HUATEC GROUP CORPORATION

HUATEC GROUP CORPORATION Professional Non Destructive Testing Equipment

Manufacturer from China
Verified Supplier
10 Years
Home / Products / Non Destructive Testing Equipment /

75 Degree Gloss Meter HGM-BZ75 Non Destructive Testing Equipment For Paper Testing

Contact Now
HUATEC GROUP CORPORATION
Visit Website
City:beijing
Province/State:beijing
Country/Region:china
Contact Person:MsShifen Yuan
Contact Now

75 Degree Gloss Meter HGM-BZ75 Non Destructive Testing Equipment For Paper Testing

Ask Latest Price
Video Channel
Brand Name :HUATEC
Model Number :HGM-BZ75
Certification :ISO, CE, GOST
Place of Origin :China
MOQ :1
Payment Terms :T/T, Western Union,Paypal
Supply Ability :500Pcs
Delivery Time :1-4working days
Packaging Details :Standard export package
test range :0.0-300.0(Gs)
test accuracy :<1.2(Gs)
stability :0.4Gs/30min
test caliber :16×48(mm)rectangular
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

High Precision 75 Degree Paper Gloss Meter HGM-BZ75 For Paper Testing

Standard

International standard ISO-8254, TAPPI - T480, ASTM-C346, ASTM-D2457, DIN67530 and China standard GB8941.3

The technical parameters follows China metrology standard JJG696-2002.


Application
BZ75 ° intelligent glossiness meter is follow ISO - 8254, TAPPI - T480, GB8941.3 standard manufacture high-precision, miniaturization, intelligent paper with glossiness plan, suitable for paper, etc, the paper is printed paper surface gloss surface lens to value measurement.

75 Degree Gloss Meter HGM-BZ75 Non Destructive Testing Equipment For Paper Testing

Parameter

The technical parameters up to JJG 696 (First-level standards).
  1. test range:0.0-300.0(Gs)
  1. test accuracy:<1.2(Gs)
  1. stability:0.4Gs/30min
  1. test caliber:16×48(mm)rectangular
  1. size:128×35×64 (mm)
  1. power:4.8V (Rechargeable battery inside)


Features

1. Small and light, real easy to be carried and used.
2. 4.8V Rechargeable battery can be used for almost 60 hours and 10000 reading.
3. High stability
4. Long-term stable light source needs no replacing forever.
5. Quartz crystal standard board, no excursion.

6. Single-chip microcomputer control circuit, the new keystrokes, light and portable, a single calibration, intelligent calibration record values

Use of equipment

Press the power switch in the measurement mode, apparatus on the sample, the samples showed that the numerical point of view at this time of the gloss value (Gs). When the "angle/ shift" button, switch different angle measurement, the corresponding point of display lights. Whether measured by that point, when measured value greater than 300.0 Gs, shows that "OVER" word.

When the electricity shortage Show "bAtt" words, at this time should be promptly charged with exclusive power rechargeable battery, charging devices plug into the mains socket on the side of charge, charging time in about four hours. Charging standards "⊕", charging the panel led by lit.

Calibration

When standard equipment on board showed that the standard plate with the corresponding numerical point of difference is greater than the nominal value of 1.2 gloss units at the following methods should be calibrated:

And measuring window on the black velvet board, press the "load switch / zero setting" button, this shows that numerical 0.0.

Black glass plate instead of the standard black velvet boards, measuring instruments on the window, rather than pressing the "calibration / test" button to enter the set, and then display the "000" and the first "0" flashing. Rather than pressing the "angle / shift" key-flashing Move right, rather than pressing the "load switch / zero setting" key "flicker" of numerical change from 0-9-0 through the press "angle / shift" and "load switch / zero setting"key to making shows that numerical standards and black glass plate corresponding nominal value of the same, at this time rather than pressing the" calibration / test "button to complete the setup. And white ceramic standard equipment on board, show that numerical standards-and-white ceramic plate angle of the corresponding nominal value of the error should not exceed ± 1.2 gloss units, it should be considered standard plate dirt, and other issues. Which point of error of work, occupation which should be in work mode in accordance with the perspective of the above process of calibration. After the completion of the steps of the samples can be measured.

Attention

The equipment built four rechargeable batteries,

Standard Delivery

Gloss meter1pc
Instrument case1pc
Standard board

2pc

A black board is used for the highlight calibration

A white board is used for the low light calibration

Battery charger1pc
English instruction manual1pc
Calibration certificate1pc

HUATEC Gloss meter Reference angle for different application

anglePoint of reference for (foreign) (China)

Application




20°

DIN-67530
ISO-2813 GB9754
ASTM-D523
ASTM-D2457 GB8807

high gloss paint, ink, plastic.


20°

ASTM-D1834
TAPPI-T653 GB8941.1

high gloss stencil, cast coated paper.


45°

ISO-2767 GB8941-2surface of aluminum and aluminum oxide.
45°

ASTM-C346 GB/T3295
ASTM-D2457 GB8807

pottery, ceramic, plastic, plastic film, Stone
45°JIS-E8741pottery, ceramic, plastic, plastic film, Stone



60°

ISO-2813 GB9754
ASTM-C584 GB9966
ASTM-D523
DIN-67530
ASTM-D2457 GB8807

Mid-gloss paint, ink, plastics, ceramics, stone.


75°

ISO-8254
TAPPI-T480 GB8941.3

copperplate paper


HUATEC has always been adhering to the first concept of customer-oriented, the products we sell will be carefully checked before shipping and then delivered to your hands.If you have any product requirements, you can contact me.Looking forward to your order.WeChat:19520504939















































Inquiry Cart 0