HUATEC GROUP CORPORATION

HUATEC GROUP CORPORATION Professional Non Destructive Testing Equipment

Manufacturer from China
Verified Supplier
10 Years
Home / Products / Hardness Testing Machine /

Thin Sample Vickers Hardness Testing Machine HV-10PDX Portable High Precision

Contact Now
HUATEC GROUP CORPORATION
Visit Website
City:beijing
Province/State:beijing
Country/Region:china
Contact Person:MsShifen Yuan
Contact Now

Thin Sample Vickers Hardness Testing Machine HV-10PDX Portable High Precision

Ask Latest Price
Video Channel
Brand Name :HUATEC
Model Number :HV-10PDX
Certification :ISO,CE,Gost
Place of Origin :China
MOQ :1 set
Payment Terms :L/C, T/T, Western Union,Paypal
Supply Ability :100 sets per month
Delivery Time :3-7 days
Packaging Details :in High quality carton
Product name :Vickers hardness tester
Model :HV-10PDX
Vickers total test force :1kgf--10kg
Vickers measurement range :8-2900HV
Hardness resolution :0.1HV
Data output :LCD
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

for thin sample HV-10PDX portable high precision Vickers hardness tester

Portable high precision thin sample Vickers hardness tester is mainly aimed at thin samples (thickness of less than 3 mm) of large parts, such as large steel plate for high precision Vickers hardness measurement.

I. Product Introduction:

Hardness tester

1. Fully meet the national Vickers hardness measurement standard;

2. Adopt electronic electric loading, high precision sensor and unique closed-loop control system.

3. Touch screen interface, easy to operate, directly select hardness scale, force value automatically change in the test parameters.

4. The test force can be automatically corrected by standard dynamometer.

5. The precision of force value is better than the national standard requirement.

Indentation measurement microscope

1. The microscope adopts large field eyepiece and achromatic objective lens, with fine tuning mechanism, stable focus and clear image. Condenser halogen light source, adjustable brightness, uniform and flat field of view;

2. Camera, take pictures and record pictures directly on the spot, with accurate magnification;

3. Coaxialized focusing mechanism makes the microscope small and stable and durable. Even with a heavy camera, it does not slide and refocus, and the image is clear and stable;

4. The microscope base is equipped with high magnetic two-dimensional mobile base which can be switched on and off. It is made of rubidium iron boron material. Users only need to turn the knob lightly to realize the on-off magnetic energy, suitable for adsorption of various complex workpiece surface, such as pipes and planes of various diameters;

5. Field of view can be adjusted in X-Y plane;

6. Gear type mechanical moving platform, even if the microscope is placed horizontally, will not slide by itself;

7. Portable LED lighting, uniform color temperature and clear photography;

8. Supporting mechanical/electrolytic field polishing equipment (optional)

Indentation measurement software section

1. Convenient carrying performance: The whole system design is small and exquisite, easy to install, simple operation.

2. Professional optical design: ensure Vickers indentation image clear, clear boundary.

3. Accurate image analysis: shape, brightness and edge calculation are integrated to improve the accuracy of measurement results.

4. With automatic measurement button, can be used for automatic measurement of standard samples, test is convenient.

5. Wide range of application: laboratory, or industrial workshop, can obtain accurate test results.

6. Powerful software functions: single measurement, batch measurement, hardness conversion table, data and image storage, database query, unqualified value alarm.

II, technical parameters

Symbol model HV-10PDX
Vickers total test force 1kgf--10kg
Vickers measurement range 8-2900HV
Holding time 0-99s
Hardness resolution 0.1HV
Test force error
  • 0.5%
Data output LCD
Data is stored The measurements are saved on the computer in EXCEL format
Conversion scale Rothschild, Brucellae
Conform to the standard GB/T4340,ASTM E92
Dimensions of parts to be measured

Plane: area ≥90X35mm, thickness ≥3mm;

Round rod (tube) : diameter > 100mm

When 60 ~ 250mm, the lower part of the magnet is fixed with V-shaped pad and chain

Software measurement resolution 0.0001mm
Digital imaging 5000000
Image acquisition Real-time display hardness indentation images, can store and print images
Measuring way Manual measurement, automatic measurement (for standard samples)
Calibration method Standard hardness block/length scale
Support language Chinese/English (optional)
power supply AC220+5%,50~60Hz,(software USB power supply)

III ,Three, hardness tester operation interface:

The main interface

Thin Sample Vickers Hardness Testing Machine HV-10PDX Portable High PrecisionThin Sample Vickers Hardness Testing Machine HV-10PDX Portable High PrecisionThin Sample Vickers Hardness Testing Machine HV-10PDX Portable High Precision

Hardness tester physical adsorption diagram

Thin Sample Vickers Hardness Testing Machine HV-10PDX Portable High Precision

Standard Accessories:

name number name number
Hardness tester main machine 1 Vickers hardness measuring microscope 1
Notebook computer 1 Diamond Vickers indenter 1
Standard hardness block 2 Usb flash drive (containing software) 1

Inquiry Cart 0