HUATEC GROUP CORPORATION

HUATEC GROUP CORPORATION Professional Non Destructive Testing Equipment

Manufacturer from China
Verified Supplier
10 Years
Home / Products / X-Ray Flaw Detector /

Handhold Personal Radiation Dosimeter FJ-3505

Contact Now
HUATEC GROUP CORPORATION
Visit Website
City:beijing
Province/State:beijing
Country/Region:china
Contact Person:MsShifen Yuan
Contact Now

Handhold Personal Radiation Dosimeter FJ-3505

Ask Latest Price
Video Channel
Brand Name :HUATEC
Model Number :FJ-3505
Certification :CE ISO
Place of Origin :CHINA
MOQ :1set
Payment Terms :T/T, Western Union,Paypal
Delivery Time :3-5 work days
Packaging Details :carton
Detector :GM tube detector with energy compensation
Energy response :40keV-1.3MeV
Alarm function :dose rate, cumulative dose, working time, etc
Data transmission :can be transmitted to the computer through the data cable (optional)
Dose equivalent rate :Hp(10) 0.1 μSv/h-100mSv/h
Cumulative dose equivalent :Hp(10) 0.0 μSv-99.99 mSv
Standard :meet GB/T13161-2015 national standard requirements
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Personal dosimeter FJ-3505

Main introduction

FJ-3505 is a multifunctional χ γ radiation dose real-time measuring instrument with halogen GM counter tube as the detector. It is designed to be worn on the human body to measure the personal dose equivalent HP (10), and it can also be used for radiation field survey and detection. User can set own alarm threshold by FJ-3505.

Technical parameter

1. Detector: GM tube detector with energy compensation

2. Energy response: 40keV-1.3MeV

3. Highly sensitive detector, strong anti-interference ability

4. Can be expanded into a series of products, equipped with wider range, higher sensitivity and other models

5. Alarm function: There are alarm functions such as dose rate, cumulative dose, working time, etc., and the alarm threshold is continuously adjustable

6. Data transmission: the measurement data can be transmitted to the computer through the data cable (optional)

7. Alarm threshold can be set by user

8. Measuring range:

 Dose equivalent rate: Hp(10) 0.1 μSv/h-100mSv/h

 Cumulative dose equivalent: Hp(10) 0.0 μSv-99.99 mSv

 Cumulative dose equivalent response error: within the range <±15% (137Cs)

9. Energy response: meet GB/T13161-2015 national standard requirements

10. Power consumption: the power consumption of the whole machine is less than 2mW, and the continuous use time of two AAA alkaline batteries is more than 700 hours

11. Temperature and humidity characteristics: at -10℃--+50℃, the error is ≤±10%; under 35℃, humidity 0-95%RH (+35℃) error ≤±10%

Application

It is suitable for the protection and personal dose monitoring of workers in radioactive applications such as industrial non-destructive testing, isotope applications, nuclear industry, hospitals, railways, civil aviation, and environmental protection.